Construction:
A wide range of copper and aluminum building wires and cables to meet today's construction wiring challenges. Designed for wet or dry locations, building wire can be armoured or non-armoured. Most building wire has a maximum voltage rating of 600V, although 1000V building wire is also available.
Building Wire Applications
Building wire is used to carry electricity into or within buildings and structures, and can be employed for a variety of commercial and residential applications - including electrical wiring systems, power generators, motors and electrical lights. ACWU and NMWU, in particular, are well-suited for direct earth burial and wiring in hazardous locations. Stranded copper wire is often used for overhead electrical transmission and distribution, and for grounding electrical systems where high conductivity and flexibility is required.
450/750V PVC Insulated (Non-Sheathed) Cables to BS 6004
Reference No 6491X
Single Core PVC Insulated
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound.
2. Colors of standard: Red, black, blue, white, brown, grey, green, yellow,
450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Harmonized Code
Designation H07V-K
Single Core PVC Insulated
XLPE insulated power cable for voltage up to 46KV1. IntroductionCross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure is simple. The long term operating temperature is 90ºC.It is convenient to use and can be laid with no restriction of different level.Our enterprise can produce both flame retardant and non-flame retardant series of XLPE power cable. Our XLPE Power cable can be produced according to our works' specifications, which are equivalent to IEC, DIN, BS and ASTM, and its some indexes are superior to standards stated above. The flame-retardant cable covers all kinds of low-smoke low-halogen , low-smoke halogen free and three classes of A,B,C. We can design and manufacture special XLPE cable according to the other standards required by the customers, such as Heavy section cut apart conductors , water-resistance , defend termites , defend mouse , and so on. 2. Scope of voltage grade and core number and cross-section a) IEC/BS/DIN Standard
b) ASTM standard
3. Service conditions and operation parameters of Cable a) Max. conductor operating temperature: 90ºC b) Short Circuit Temperature:250ºC c) Ambient temperature: 30ºC d) Soil temperature: 20ºC e) Depth of laying in direct : 0.8m f) Thermal Resistance of soil : 150ºC.cm/W g) Thermal Resistance of ducts : 120ºC.cm/W Send your message to this supplier | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound.
2. Colors of standard: Red, black, brown, grey, orange, white, violet, pink, green/yellow, yellow
300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6181y
Single Core PVC Insulated and PVC Sheathed
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of Sheath mm | Mean overall diameter | Approx. Net weight per km Kg | ||
Nominal Cross-sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | |||
1.0 | 1/1.13 | 0.6 | 0.8 | 3.8 | 4.5 | 28 |
1.5 | 1/1.38 | 0.7 | 0.8 | 4.2 | 4.9 | 35 |
2.5 | 1/1.78 | 0.8 | 0.8 | 4.8 | 5.8 | 50 |
4 | 7/0.85 | 0.8 | 0.9 | 5.4 | 6.8 | 75 |
6 | 7/1.04 | 0.8 | 0.9 | 6.0 | 7.4 | 100 |
10 | 7/1.35 | 1.0 | 0.9 | 7.2 | 8.8 | 155 |
16 | 7/1.70 | 1.0 | 1.0 | 8.4 | 10.5 | 225 |
25 | 7/2.14 | 1.2 | 1.1 | 10.0 | 12.5 | 340 |
35 | 19/1.53 | 1.2 | 1.1 | 11.0 | 13.5 | 445 |
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Red, black. Sheath colour: Grey or white.
Reference No 6192y
Flat Twin
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of Sheath mm | Mean overall Dimensions | Approx. Net weight per km Kg | ||
Nominal Cross-sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | |||
1.0 | 1/1.13 | 0.6 | 0.9 | 4.0*6.2 | 4.7*7.4 | 55 |
1.5 | 1/1.38 | 0.7 | 0.9 | 4.4*7.0 | 5.4*8.4 | 70 |
2.5 | 1/1.78 | 0.8 | 1.0 | 5.2*8.4 | 6.2*9.8 | 105 |
4 | 7/0.85 | 0.8 | 1.0 | 5.6*9.6 | 7.2*11.5 | 150 |
6 | 7/1.04 | 0.8 | 1.1 | 6.4*10.5 | 8.0*13.0 | 205 |
10 | 7/1.35 | 1.0 | 1.2 | 7.8*13.0 | 9.6*16.0 | 325 |
16 | 7/1.70 | 1.0 | 1.3 | 9.0*15.5 | 11.0*18.5 | 465 |
Notes
1. Conductor of high conductivity copper, wires insulated with PVC compound. Sheathed with PVC compound.
2. Color of sheath: Grey or white,
300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6193y
Three Core (Flat)
Size of conductor | Nominal Thickness of insulation mm | Nominal thickness of Sheath mm | Mean overall diameter | Approx. Net weight per km Kg | ||
Nominal Cross-sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | |||
1.0 | 1/1.13 | 0.6 | 0.9 | 4.0*8.4 | 4.7*9.8 | 77 |
1.5 | 1/1.38 | 0.7 | 0.9 | 4.4*9.8 | 5.4*11.5 | 100 |
2.5 | 1/1.78 | 0.8 | 1.0 | 5.2*11.5 | 6.2*13.5 | 150 |
4 | 7/0.85 | 0.8 | 1.1 | 5.8*13.5 | 7.4*16.5 | 230 |
6 | 7/1.04 | 0.8 | 1.1 | 6.4*15.0 | 8.0*18.0 | 300 |
10 | 7/1.35 | 1.0 | 1.2 | 7.8*19.0 | 9.6*22.5 | 485 |
16 | 7/1.70 | 1.0 | 1.3 | 9.0*22.0 | 11.0*26.5 | 700 |
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Red, yellow and blue, (yellow in centre) Sheath colors: Grey or white.
Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor
Size of conductor | Nominal thickness Of insulation mm | Size of earth conductivity Conductor No. /mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross- Sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | ||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*7.2 | 4.7*8.6 | 70 |
1.5 | 1/1.38 | 0.7 | 1/1.13 | 0.9 | 4.4*8.2 | 5.4*9.6 | 85 |
2.5 | 1/1.78 | 0.8 | 1/1.13 | 1.0 | 5.2*9.4 | 6.2*11.0 | 120 |
4 | 7/0.85 | 0.8 | 1/1.38 | 1.0 | 5.6*10.5 | 7.2*13.0 | 175 |
6 | 7/1.04 | 0.8 | 1/1.78 | 1.1 | 6.4*12.5 | 8.0*15.0 | 240 |
10 | 7/1.35 | 1.0 | 7/0.85 | 1.2 | 7.8*15.5 | 9.6*19.0 | 390 |
16 | 7/1.70 | 1.0 | 7/1.04 | 1.3 | 9.0*18 | 11.0*22.0 | 560 |
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Red and black. Sheath colors: Grey or white.
300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6243y
Three-core (Flat) with Bare
Earth-continuity Conductor
Size of conductor | Nominal thickness Of insulation mm | Size of Earth- Conduct -ivity Conductor No/mm | Nominal thickness Of sheath mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross- Sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper Limit mm | ||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*9.6 | 4.7*11.0 | 92 |
1.5 | 1/1.38 | 0.7 | 1/1.13 | 0.9 | 4.4*10.5 | 5.4*12.5 | 115 |
2.5 | 1/1.78 | 0.8 | 1/1.13 | 1.0 | 5.2*12.5 | 6.2*14.5 | 170 |
4 | 7/0.85 | 0.8 | 1/1.38 | 1.1 | 5.8*14.5 | 7.4*18.0 | 255 |
6 | 7/1.04 | 0.8 | 1/1.78 | 1.1 | 6.4*16.5 | 8.0*20.0 | 340 |
10 | 7/1.35 | 1.0 | 7/0.85 | 1.2 | 7.8*21.0 | 9.6*25.5 | 550 |
16 | 7/1.70 | 1.0 | 7/1.04 | 1.3 | 9.0*24.5 | 11.0*29.5 | 790 |
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Red, yellow and blue(yellow in centre) Sheath colors: Grey or white.
300/300V PVC Insulated Parallel Flexible Cords to BS 6500
Reference No 2812X RVB
Twin Core
Size of conductor | Nominal Thickness Of insulation mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross-sectional area mm2 | Number and diameter of wires No/mm | Lower Limit mm | Upper Limit mm | ||
0.5 | 28/0.15 | 0.8 | 2.5X5.0 | 3.0X6.0 | 24 |
0.75 | 42/0.15 | 0.8 | 2.7X5.4 | 3.2X6.4 | 29 |
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound.
2. One core with a ridge for identification.
300/500V and 450/750V PVC Insulated Flexible Cords to BS 6500/6004
Reference No 2491X
Single Core
Size of conductor | Nominal Thickness Of insulation mm | Mean overall diameter Upper limit mm | Approx. Net weight per km Kg | |
Nominal Cross-sectional area mm2 | Number and diameter of wire No/mm | |||
0.5 | 16/0.20 | 0.6 | 2.6 | 10 |
0.75 | 24/0.20 | 0.6 | 2.8 | 13 |
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5* | 30/0.25 | 0.7 | 3.5 | 20 |
2.5* | 50/0.25 | 0.8 | 4.2 | 32 |
4.0* | 56/0.30 | 0.8 | 4.8 | 49 |
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound.
2. Standard colors: Red. Black, white, blue, brown, grey and green/yellow.
*: Rating Voltage 450/750V
300/500V PVC Insulated Twisted Twin Flexible Cords to BS 6500
Reference No 2492X
Twisted Twin
Size of conductor | Nominal Thickness Of insulation mm | Mean overall diameter of Each core Upper limit mm | Approx. Net weight per km Kg | |
Nominal Cross-sectional area mm2 | Number and diameter of wires mm | |||
0.5 | 16/0.20 | 0.6 | 4.6 | 20 |
0.75 | 24/0.20 | 0.6 | 5.0 | 26 |
1.0 | 32/0.20 | 0.6 | 5.4 | 33 |
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound.
2. Two cores twisted together.
300/300V PVC Insulated PVC Sheathed Parallel Twin Light Flexible Cords to BS 6500
Reference No 2192Y
Parallel Twin
Size of conductor | Nominal Thickness Of insulation mm | Nominal Thickness Of sheath mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross- Sectional area mm2 | Number and diameter of wires No. /mm | Upper Limit mm | Upper Limit mm | |||
0.5 | 16/0.20 | 0.5 | 0.6 | 3.0X4.8 | 3.6X6.0 | 27 |
0.75 | 24/0.20 | 0.5 | 0.6 | 3.2X5.2 | 3.9X6.4 | 34 |
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Blue and brown. Sheathed colors: Grey, white or black.
300/300V PVC/PVC Sheathed Circular Light Flexible Cords to BS 6500
Reference No 2182Y
Twin Core
Size of conductor | Nominal Thickness Of insulation mm | Nominal Thickness Of sheath mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross- Sectional Area mm2 | Number and diameter of wires No. /mm | Upper Limit mm | Upper Limit mm | |||
0.5 | 16/0.20 | 0.5 | 0.6 | 4.8 | 6.0 | 36 |
0.75 | 24/0.20 | 0.5 | 0.6 | 5.2 | 6.4 | 45 |
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Blue and brown. Sheathed colors: Grey, white or black.
Reference No 2183Y
Three Core
Size of conductor | Nominal Thickness of insulation mm | Nominal Thickness of Sheath mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross- Sectional area mm2 | Number and diameter of wires No/mm | Lower Limit mm | Upper Limit mm | |||
0.5 | 16/0.2 | 0.5 | 0.6 | 5.0 | 6.2 | 44 |
0.75 | 24/0.2 | 0.5 | 0.6 | 5.4 | 6.8 | 55 |
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Green/ yellow blue and brown. Sheathed colors: Grey, white or black.
300/500V PVC/PVC Sheathed Parallel Twin Flexible Cords to BS 6500
Reference No 3192Y
Parallel Twin
Size of conductor | Nominal Thickness of insulation mm | Nominal thickness of Sheath mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross- Sectional area mm2 | Number and diameter of wires No. /mm | Lower Limit mm | Upper Limit mm | |||
0.75 | 24/0.20 | 0.6 | 0.8 | 3.8*6.0 | 5.2*7.6 | 47 |
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Blue and brown. Sheathed colors: Grey white or black.
300/500VPVC/PVC Sheathed Circular Flexible Cords to BS 6500
Reference No 3182Y
Twin Core
Size of conductor | Nominal Thickness of insulation mm | Nominal Thickness of Sheath mm | Mean overall dimensions | Approx. Net weight per km Kg | ||
Nominal Cross- Sectional Area mm2 | Number and diameter of wires No/mm | Lower Limit mm | Upper Limit mm | |||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 63 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 73 |
1.25 | 40/0.20 | 0.7 | 0.8 | 7.0 | 8.6 | 84 |
1.5 | 30/0.25 | 0.7 | 0.8 | 7.4 | 9.0 | 95 |
2.5 | 50/0.25 | 0.8 | 1.0 | 8.9 | 11.0 | 145 |
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2. Core colors: Blue and brown. Sheathed colors: Grey. White or black.